Product Center

Contact Information

Consultation Hotline:

+86 18062109704

Email: yqzhu@nengshi.com

Address: No. 336, Heping Avenue, Wuchang District, Wuhan City

Message Inquiry

Sodium Sensor

Technical Features:
Our company’s online sodium electrodes are compatible with all domestically produced and imported sodium analyzers, including models from Orion and Honeywell in the United States, Wartron, Polymetron in France, Swan in Switzerland, and others. We guarantee that our sodium electrodes deliver equivalent quality and service life to imported counterparts.

Contact for consultation
NA4300

NA4300

As shown in the figure:
The sodium electrode and reference electrode can be used in conjunction with various domestically produced online sodium analyzers.

The connection method and dimensions are exactly the same as those of the original power electrode.

 

Selection and Technical Performance:

Model

Sodium electrode NA4300

Reference Electrode NR3100

Range (μg/L)

0~1000

Temperature (°C)

0~50

Material

glass

Dimensions (mm)

φ12×120

Connection method

Fixed wire (length customizable)

ASNA703

ASNA703

As shown in the figure:
Composite sodium electrode, compatible with various online sodium analyzers.

The connection method and dimensions are exactly the same as the original distribution system.

 

Selection and Technical Performance:

Model Range (μg/L) Temperature (°C) Remarks
Sodium electrode ASNA703 0-1000 5-50 Can be used with various sodium meters.
NA4311

NA4311

As shown in the figure:
The sodium electrode and reference electrode can be directly used with the ORION sodium meter, fully replacing imported electrodes.

Fully compatible with the dimensions and connection method of imported electrodes.

The reference electrode replenishment solution can fully replace imported replenishment solutions.

 

Selection and Technical Performance:

Model Range (μg/L) Temperature (°C) Remarks
Sodium electrode NA4311 0-1000 5-50 Specially designed for the 1118EL sodium meter
Reference NR3102   0-100
S3102 Reference electrode replenishment solution, specially formulated for NR3102 and 10058 electrodes, fully capable of replacing imported alternatives.
Sodium electrode NA1045 0-1000 5-50 Specifically matched for 1118AO or 1811LL sodium meters
Reference Electrode NR1045   0-100
S1045 Reference electrode replenishment solution, specifically formulated for NR1045 and 10046 electrodes, can fully replace imported alternatives.
NA7200

NA7200

As shown in the figure:
The sodium electrode and reference electrode can be used directly with the SWAN sodium meter, fully replacing imported electrodes.

Fully compatible with SWAN sodium electrode in terms of size and connection method.

The reference electrode replenishment solution can fully replace imported replenishment solutions.

 

Selection and Technical Performance:

Model Range (μg/L) Temperature (°C) Remarks
Sodium electrode NA7200 0-100 5-50 Specially designed for SWAN sodium meters
Reference Electrode NR7200   0-100  
S7200 Reference electrode replenishment solution, specifically formulated for NR7200 and SWAN imported reference electrodes, can fully replace imported counterparts.
NA9245 Series

NA9245 Series

As shown in the figure:
The sodium electrode and reference electrode can be used directly with the Polymetron sodium meter, fully replacing imported electrodes.

The electrode dimensions and connection methods are fully compatible with the Polymetron 8873, 9073, and 9245 sodium meters.

The reference electrode replenishment solution can fully replace imported replenishment solutions.

 

Selection and Technical Performance:

Model Range (μg/L) Temperature (°C) Remarks
Sodium electrode NA8873 0-100 5-50 Specifically matched for the 8873 sodium meter
Sodium electrode NA9073 0-100 5-50 Specifically matched for the 9073 sodium meter
Sodium electrode NA9245 0-100 5-50 Specifically matched for the 9245 sodium meter
Reference Electrode NR9073   0-100  
Reference Electrode NR9245   0-100  
S9073 Reference electrode replenishment solution, specifically formulated for NR9073, 9245, and imported reference electrodes, can completely replace imported products.

 

NA1048

NA1048

As shown in the figure:
The sodium electrode and reference electrode can be used in conjunction with ABB sodium meters, fully replacing imported electrodes.

Fully compatible with the dimensions and connection method of imported electrodes.

 

Selection and Technical Performance:

Model Range (μg/L) Temperature (°C) Remarks
Sodium electrode NA1048 0-1000 5-50 Specially matched ABB sodium meter
Reference Electrode NR1048   0-100
NA7082

NA7082

  As shown in the figure:
The sodium electrode and the reference electrode can be used respectively with Honeywell sodium meters, fully replacing imported electrodes.

Fully compatible with the dimensions and connection method of imported electrodes.

 

Selection and Technical Performance:

Model Range (μg/L) Temperature (°C) Remarks
Sodium electrode NA7082 0-1000 5-50 Specifically matched for Honeywell sodium meters
Reference Electrode NR7080   0-100