Message InquirypH Sensors
Technical Features:
All pH Sensors manufactured by our company are developed using German technology and produced in strict accordance with German manufacturing processes. To ensure product quality, all key raw materials are directly imported from overseas. Currently, most of our products are exported to more than ten countries, including the United States, Germany, France, the United Kingdom, Australia, Russia, and South Korea. Years of practical experience have proven that our pH Sensors boast superior performance and stable, reliable quality. Our comprehensive range of pH Sensors can be widely applied in various industrial production control processes!
ASP3211 Series
As shown in the figure:
● PG13.5 threaded mounting, internationally recognized standard
● The Sensor comes with a fixed lead, the length of which can be adjusted according to user requirements
● The Sensor is suitable for pure water with a conductivity ≥1 μS/cm
● Measurement range: 0–14 pH; Zero potential: E0=7pH; Temperature range: 0–110°C
● Pressure resistance: 0.6 MPa
● Dimensions: ∅12×120mm, 225mm, or other sizes
● Outer tube material: glass
● Temperature compensation resistors: 10 kΩ, PT100, PT1000, 2.252 kΩ, etc
Model Selection:
ASP2211 Combination Sensor
ASP3211 Combination Sensor with Thermistor
ASP3211D Digital Sensor with RS485 Output, No Calibration Required, Plug and Play
ASYS3811 Series
As shown in the figure:
● The Sensor is with fixed cable or VP connector, and the wire length can be customized according to user requirements.
● Threaded mounting; thread size PG13.5, an internationally recognized standard
● Stable zero point with minimal drift
● Fast Sensor Response (up to T98% < 60 seconds)
● Measurement range: 0–20 mg/L
● Pressure resistance: 0.4 MPa
● Temperature range: 0–60°C
● Outer tube dimensions: ∅12×120mm
● Outer tube material: Plastic
● Temperature-compensated resistors: 10 kΩ, PT100, PT1000, 2.252 kΩ, 22 kΩ
Model Selection:
● Galvanic:
ASYYS3851 VP Head Connection
ASYYS3811 Fixed Wire
● Polarographic:
ASYS3851 VP Connector
ASYS3811 Fixed Cable
3300D
As shown in the figure:
● Can be used in conjunction with our company’s pH, ORP, DO, conductivity, and turbidity Sensors
● Features display, signal transmission, alarm, and automatic cleaning control functions
● Supports tag number entry
● Provides two 4–20 mA outputs for transmitting the primary measured parameter and the temperature measurement value
● Provides three relay outputs (upper/lower limit alarms and automatic cleaning), supporting both normally open and normally closed wiring configurations
● Provides password management permissions for operations to prevent unauthorized modification of parameter settings
● Supports external RS-485 communication
● Supports Chinese/English menu display (default is Chinese at factory settings)
● The entire unit meets an IP67 protection rating, allowing for outdoor, open-air installation and operation
Technical Indicators:
| Main Functions | Measurement/Display/Loosening/Alarm/Automatic Cleaning |
| Screen Parameters | 3.5-inch high-definition monochrome display (320×240) |
| Measurement range |
pH: 0–14.00 pH ORP: -2000 mV to +2000 mV Conductivity: 0–400 mS/cm; Inductive conductivity: 0–2000 mS/cm; Polarographic dissolved oxygen: 0–20 mg/L; Fluorescence-based dissolved oxygen: 0–50 mg/L Turbidity: 0.1–4000 NTU |
| Temperature | 0–99.9°C |
| Automatic Temperature Compensation | Yes |
| Analog Output |
2-wire (4–20) mA (500 Ω load), accuracy: ±0.2% |
| Relay output |
Three-channel open/normally closed contact output, 250 Vac / 30 Vdc / 3 A (max) |
| Alarm Settings | Upper/Lower Limit Alarm (with configurable lookback and delay) |
| Power supply | Compatible with 220VAC and 24VDC |
| Communication interface | RS485 |
| Protection rating | IP67 |
| External dimensions | 144×152×113mm |
| Opening size | 137×137 mm |
| Installation Method | Panel-mounted/Pipe-mounted/Wall-mounted |
3000D
As shown in the figure:
● Can be used in conjunction with our company’s pH, ORP, DO, conductivity, and turbidity Sensors
● Equipped with display, transmission, alarm, and communication functions
● Supports tag number entry
● Provides one 4–20 mA output for transmitting the primary measured parameter and temperature measurement value.
● Provides two relay outputs (upper/lower limit alarm and automatic cleaning), supporting both normally open and normally closed wiring configurations.
● Provides password management permissions for operations to prevent unauthorized modification of parameter settings.
● Supports external RS-485 communication
● Supports Chinese/English menu display (default is Chinese at factory settings)
● The entire unit meets an IP67 protection rating, allowing for outdoor, open-air installation and operation.
Technical Indicators:
Main Functions | Display/Transmit/Alarm/Communication |
Screen Specifications | 2.8-inch high-definition monochrome screen (320×240) |
Measurement range | pH: 0–14.00 pH ORP: -2000 mV to +2000 mV Conductivity: 0–400 mS/cm; Inductive Conductivity: 0–2000 mS/cm Polarographic dissolved oxygen: 0–20 mg/L; Fluorescence-based dissolved oxygen: 0–50 mg/L Turbidity: 0.1–4000 NTU |
Temperature | 0–99.9°C |
Analog Output | 4–20 mA transmitter output , Accuracy: ±0.2% (load 500 Ω) |
Relay output | Two-way normally open and normally closed contact outputs, 250 VAC / 30 VDC / 3 A (max) |
Alarm Settings | Upper/Lower Limit Alarm (with configurable lookback and delay) |
Power supply | Compatible with 220VAC and 24VDC |
Communication Interface | RS485 |
Protection rating | IP67 |
External dimensions | 113.5*118*136mm |
Opening size | 92*92mm |
Installation Method | Panel-mounted/Pipe-mounted/Wall-mounted |
3300D
As shown in the figure:
● Can be used in conjunction with our company’s pH, ORP, DO, conductivity, and turbidity sensors
● Features display, signal transmission, alarm, and automatic cleaning control functions
● Supports tag number entry
● Provides two 4–20 mA outputs for transmitting the primary measured parameter and the temperature measurement value
● Provides three relay outputs (upper/lower limit alarms and automatic cleaning), supporting both normally open and normally closed wiring configurations
● Provides password management permissions for operations to prevent unauthorized modification of parameter settings
● Supports external RS-485 communication
● Supports Chinese/English menu display (default is Chinese at factory settings)
● The entire unit meets an IP67 protection rating, allowing for outdoor, open-air installation and operation
Technical Indicators:
| Main functions | Measurement/Display/Loosening/Alarm/Automatic Cleaning |
| Screen spesifications | 3.5-inch high-definition monochrome display (320×240) |
| Measurement range |
pH: 0–14.00 pH ORP: -2000 mV to +2000 mV Conductivity: 0–400 mS/cm; Inductive conductivity: 0–2000 mS/cm; Dissolved oxygen: 0–20 mg/L Fluorometric oxygen: 0–50 mg/L Turbidity: 0.1–4000 NTU |
| Temperature | 0–99.9°C |
| Analog output |
2-wire (4–20) mA (500 Ω load), accuracy: ±0.2% |
| Relay output |
Three-channel open/normally closed contact output, 250 Vac / 30 Vdc / 3 A (max) |
| Alarm settings | Upper/Lower Limit Alarm (with configurable lookback and delay) |
| Power supply | Compatible with 220VAC and 24VDC |
| Communication interface | RS485 |
| Protection rating | IP67 |
| External dimensions | 144×152×113mm |
| Installation size | 137×137 mm |
| Installation method | Panel-mounted/Pipe-mounted/Wall-mounted |
3000D
As shown in the figure:
● Can be used with our company’s pH, ORP, DO, conductivity, and turbidity Sensors. Used as a set
● Equipped with display, transmission, alarm, and communication functions
● Supports tag number entry
● Provides one 4–20 mA output for transmitting the primary measured parameter and temperature measurement value.
● Provides two relay outputs (upper/lower limit alarm and automatic cleaning), supporting both normally open and normally closed wiring configurations.
● Provides password management permissions for operations to prevent unauthorized modification of parameter settings.
● Supports external RS-485 communication
● Supports Chinese/English menu display (default is Chinese at factory settings)
● The entire unit meets an IP67 protection rating, making it suitable for outdoor, open-air installation and operation.
Technical Indicators:
Main functions | Display/Transmit/Alarm/Communication |
Screen specifications | 2.8-inch high-definition monochrome display (320×240) |
Measurement range | pH: 0–14.00 pH ORP: -2000 mV to +2000 mV Conductivity: 0–400 mS/cm; Inductive conductivity: 0–2000 mS/cm; Dissolved oxygen: 0–20 mg/L Fluorometric oxygen: 0–50 mg/L Turbidity: 0.1–4000 NTU |
Temperature | 0–99.9°C |
Analog output | 4–20 mA transmitter output , Accuracy: ±0.2% (load 500 Ω) |
Relay output | Two-way normally open and normally closed contact outputs, 250 VAC / 30 VDC / 3 A (max) |
Alarm settings | Upper/Lower Limit Alarm (with configurable lookback and delay) |
Power supply | Compatible with 220VAC and 24VDC |
Communication interface | RS485 |
Protection rating | IP67 |
External dimensions | 113.5*118*136mm |
Installation size | 92*92mm |
Installation method | Panel-mounted/Pipe-mounted/Wall-mounted |
ASPSRT2-2121D Series
As shown in the figure:
● Multi-parameter digital sensor with RS485 output directly converts analog signals into digital signals
● Data is stored inside the Sensor, such as important parameters like zero point and slope
● Plug-and-play, no need to calibrate the Sensor, convenient to use without a transmitter
● The Sensor’s digital output can be directly converted into WIFI or GPRS signals for wireless transmission
● Data can be transmitted both over short and long distances, with stable and reliable measurement values
● 3/4 NPT threaded connection for secure and reliable sealing
● Pressure resistance: 0.6 MPa, zero potential: E 0 =7 pH
● Dimensions: ∅28×176mm
● Outer tube material: plastic
● pH range: 0–14 pH
● ORP range: ±2000 mV
● Conductivity range: 0–20,000 μS/cm
● Temperature range: 0–80°C
Model Selection:
● Intelligent 3-in-1 Sensor with RS485 Output:
ASPSRT2-2121D pH/ORP/Temperature
ASPSCT2-2121D pH/EC/Temperature
ASPSRCT2-2121D ORP/EC/Temperature
● Intelligent 4-in-1 Sensor with RS485 Output:
ASPSRCT2-2121D pH/ORP/EC/Temperature